Please use this identifier to cite or link to this item: http://repository.i3l.ac.id/jspui/handle/123456789/1005
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPelasula, Mercy Meitrecia-
dc.date.accessioned2024-01-24T03:19:11Z-
dc.date.available2024-01-24T03:19:11Z-
dc.date.issued2024-01-18-
dc.identifier.urihttp://repository.i3l.ac.id/jspui/handle/123456789/1005-
dc.description.abstractPT Kalbe Milko Indonesia is a toll manufacturing company which specializes in the production of sterilized liquid products like milk, using retort technology. The QA department is responsible for maintaining the quality of the produced liquids through conducting daily physicochemical analysis and monthly stability analysis to ensure the product parameters are within the determined standard range. Milk composition varies based on various internal and external factors including the heating process during the production. This leads to the necessity of conducting quality control. In PT Kalbe Milko Indonesia, physicochemical analysis is one of the efforts to maintain the milk product quality. Density is one of the physicochemical properties of milk that is measured as a parameter of quality standards. Several instruments (pycnometer, the lactodensimeter with 1.1 g/mL scale and 1.06 g/mL scale) are available at the laboratory to measure the density of sterilized milk. With regards to method standardization and variations in the performance of the instruments, the result of density measurements of sterilized milk using the three instruments were compared using the milk samples from 10 batches of production. Along with that, the density within the production batches were also compared. Significant differences were observed in the result of density measurement using the three instruments as well as the density result within production batches. Factors affecting these differences include temperature condition, instrument calibration, the scale of the lactodensimeter, variations in the composition of ingredients as well as production processes, and the possible human error.en_US
dc.language.isoenen_US
dc.publisherIndonesia International Institute for Life Sciencesen_US
dc.relation.ispartofseriesEP FT-031;EP24-031-
dc.subjectDensityen_US
dc.subjectlactodensimeter 1.1 g/mL scaleen_US
dc.subjectlactodensimeter 1.06 g/mL scaleen_US
dc.subjectpycnometeren_US
dc.subjectsterilized milken_US
dc.titleMeasurement Comparison Of The Density Of Sterilized Milk Using Lactodensimeter And Pycnometeren_US
Appears in Collections:FT

Files in This Item:
File Description SizeFormat 
Abstract.pdfAbstract59.75 kBAdobe PDFView/Open
Chapter 1.pdfChapter 1155.64 kBAdobe PDFView/Open
Cover.pdfCover267.13 kBAdobe PDFView/Open
EP2024_FT_Mercy Meitrecia Pelasula.pdf
  Restricted Access
Full Text2.66 MBAdobe PDFView/Open Request a copy
References.pdfReferences68.93 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.